COMMERCIAL

RESIDENTIAL    
 

 120 Eldredge Street

 120 Eldredge Street

 

 

 Binghamton, NY  13902-2460

 Binghamton, NY  13902-2460

 Ithaca, NY

Toll Free

 800-456-1913

 800-456-1913

 800-456-1913

Phone

 607-722-7221

 607-722-7221

 607-277-1913

Fax

 607-722-7359

 607-722-7359

 607-722-7359

Revised 7/23/08

* * Keeping the Weather out Since 1913 * *

5 Generation Family Commitment

Home
Commercial
Residential
Paint & Finish Center
Useful Info
Work Opportunities
Contact Us

New NY State Building Code

 

New York State recently adopted the National BOCA building codes.  This impacts New York State construction in several ways:

 

 

R907.3 - Recovering versus replacement

 

New roof coverings shall not be installed without first removing existing roof coverings where any of the following conditions occur:

 

  1. Where the existing roof or roof covering is water-soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing.

  2. Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile

  3. Where the existing roof has two or more applications any type of roofing.

 

Exceptions:

 

  1. Complete and separate roofing systems such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and that do not rely on existing roofs and roof coverings for support shall not require the removal of existing roof coverings.

  2. Metal paned, metal shingle, and concrete and clay tile roof coverings shall be permitted to be installed over existing wood shake roofs when applied in accordance with Section R907.4

 

 

R905.2.7.1 - Ice Protection

 

In areas where the average daily temperature in January is 25 degrees F (-4 degrees C) or less or when Table R301.2(1) criteria so designates, an ice barrier that consists of at least two layers of underlayment cemented together or of a self-adhering polymer modified bitumen sheet, shall be used in lieu of normal underlayment and extend from the eave's edge to a point at least 24 inches (610 mm>) inside the exterior wall line of the building.

 

Feet of Ice Backup Protection to Meet NY State Building Code

(Backup protection is available only in 3 foot rolls)

 

Overhang

(Inches)

Roof Pitch
4/12 5/12 6/12 7/12 8/12 9/12 10/12 11/12 12/12
2

3'

3' 3' 3' 3' 3' 3' 3' 3'
4 3' 3' 3' 3' 3' 3' 6' 6' 6'
6 3' 3' 3' 3' 6' 6' 6' 6' 6'
8 3' 3' 3' 6' 6' 6' 6' 6' 6'
10 3' 6' 6' 6' 6' 6' 6' 6' 6'
12 6' 6' 6' 6' 6' 6' 6' 6' 6'

Actual Rafter Distance (Inches) From Eave to a Point Above 2' From Outside Wall

Overhang

(Inches)

Roof Pitch
4/12 5/12 6/12 7/12 8/12 9/12 10/12 11/12 12/12
2

27.4

28.2 29.1 30.1 31.2 32.5 33.8 35.3 36.8
4 29.5 30.3 31.3 32.4 33.7 35.0 36.4 38.0 39.6
6 31.6 32.5 33.5 34.7 36.1 37.5 3931 40.7 42.4
8 33.7 34.7 35.8 37.0 38.5 40.0 41.7 43.4 45.3
10 35.8 36.8 3830 39.4 40.9 42.5 44.3 46.1 48.1
12 37.9 39.0 40.2 41.7 43.3 45.0 46.9 48.8 50.9

 

 
Copyright © 2008 BSR, all rights reserved